Specification:
Condition: 100% Brand New
Item Type: Time Relay Control Module
Material: Plastic
Color: As picture shown
Model: JYSJ13
Maximum Relay Control Current: 20A
Instructions for Use:
Setting of Working Parameters:
Press and hold the SET button without letting go. After 0.5 seconds, the display shows PXX, press UP and DOWN to change the working mode. After selecting the working mode, short press the SET key to enter the A time setting, the screen displays Axxx, press the UP and DOWN keys to modify the A time parameter, press theandkeys shortly to add or subtract 1, long press to quickly add or subtract 10, press The S key can set the position of the decimal point. After setting the A time, press the SET button to set the B time, and the screen displays bxxx. At this time, press the UP and DOWN buttons to modify the B time parameter, press the UP and DOWN buttons to shortly press to add or subtract 1, and long press to quickly add or subtract 10. Press the S4 key to set the position of the decimal point. After setting the B time, press the SET key again to enter CXXX, press the SET key again to enter dXXX, and press the SET key again to exit the setting state and save all parameters.
The above settings such as B time or other time have no effect, no need to set, press SET to skip.
P2 is the stop and start function (triggered as described below). The individual functions are invalid.
The meaning of the decimal point position:
Ax.xx The decimal point is in the hundred, and the time range is 0.01~9.99 seconds
Axx.x The decimal point is in the tenth place, and the time range is 0.1~99.9 seconds
Axxx. The decimal point is in the ones place, and the time range is 1~999 seconds
Axxx has no decimal point, the time range is 1~999 minutes
Turn off the display: In the nonsetting state, press the S key to turn off the display, and then press it again to turn it on again.
Operating Mode:
P00: Invalid (skip)
P01: The relay is disconnected after poweron or triggered, and the relay is closed after a delay of time A
P02: Pullin after poweron or trigger, the relay is disconnected after delay A time
P03: Jog mode, pullin with signal, disconnect without signal
P04: Selflocking mode, the relay state flip once after each trigger
P05: After triggering, the relay pulls in and stops after a delay of time A. Repeated triggering is not allowed during the delay period
P06: After triggering, the relay is closed, and it will stop after a delay of A time. Repeated triggering during the delay period will retiming
P07: After triggering, the relay is closed, and it stops after a delay of A second. Repeated triggering during the delay period, the time will accumulate
P08: After triggering, the relay is closed, and it will stop after a delay of A second, and it can stop immediately after triggering again during the delay.
P09: After triggering, the relay is closed. After the signal disappears, the delay will stop for A second, and the trigger will restart during the delay.
P10: After poweron, pullin time A, disconnect time B, infinite loop
P11: When there is a continuous signal, pull in A time, disconnect B time, infinite loop, stop immediately after the signal disappears
P12: Trigger once, pull in A time, disconnect B time, infinite loop, trigger again to stop
P13: The relay is switch on when the power is on, the relay is disconnected after triggering, and the relay is switch on after the delay time A
P14: There is a continuous signal, the relay is closed after the time A is exceeded, and the signal disappears and the relay is disconnected
P15: The relay with continuous signal is disconnected, and the relay is closed after the signal disappears for more than A time
P16: When there is a continuous signal for more than A time, the relay is closed, and after the signal disappears for more than A time, the relay is disconnected
P17: The relay is closed after a continuous signal exceeds the A time. After the signal disappears, the relay is disconnected after a continuous signal exceeds the A time.
P18: Trigger, the relay will be closed after time A is exceeded, and triggered again, the relay will be disconnected after time A is exceeded
P19: There is a continuous signal that the relay pulls in for A time and then stops, and then if the signal disappears, the relay pulls in for A time and then stops
P20: There is pulse signal (rising edge or falling edge), the relay stops, and there is no pulse signal, the relay will be closed after delay A time [continuous high level or continuous low level is considered as no pulse]
P21: After poweron, the relay will be closed after the delay time A, and stop after the time B is closed
P22: After triggering, the relay will be closed after delaying time A, and it will stop after closing time B
P23: There is a continuous signal and the relay is closed after the time A is exceeded, and it stops after the time B is closed
P24: After triggering, the relay stops after A time, and then counts B time after it stops. It cannot be triggered again within A+B time
P25: After triggering, the relay stops after closing A time, timing B time, and then closing A time and then stop. During this time, it cannot be triggered repeatedly
P26: Counting mode, rising edge trigger, each time a rising edge is detected, the value is +1, the maximum count is 9999, the maximum frequency is 20Hz, short press the S1 key to clear
P27: Counting mode, falling edge trigger, each time a falling edge is detected, the value is +1, the maximum count is 9999, the maximum frequency is 20Hz, short press the S1 key to clear
P28: Counting mode, rising edge trigger value +1, maximum 9999, Maximum 20Hz, when the count value is equal to the d parameter, the relay is closed and the program stops. Press the S1 button at any time to reset
P29: Counting mode, rising edge trigger value +1, maximum 9999, Maximum 20Hz, when the count value is equal to parameter d, the program will automatically reset after the relay pulls in for A time. Press the S1 button at any time to reset
P30: After triggering, delay time A and then pull in (falling edge trigger), pull in after B time, disconnect, count once, stop when the number of counts reaches d parameter, if there is trigger (rising) during the A time delay Edge) will reset
P31: After poweron, count down the time c and then automatically trigger. After the trigger, it will be closed after a delay of time A, and disconnected after the time of pullin B. It is counted once. When the number of counts reaches the d parameter, a new cycle is restarted.
Features:
1Multiple functions, a total of 31 working modes. The maximum control current of the relay is 20A. 2Multiple supply voltages are optional: DC5V, DC 12V, DC24V, which can meet your different needs. 3The output terminal is isolated from the circuit by a relay, which can control lowvoltage electrical appliances, direct current, etc., and can also control lines. 4To meet various testing and automatic control applications, the delay time is adjustable from 0.01 second to 999 minutes. 5Built to meet standard specification, strictly follow factory quality control.
Package List:
1 x Time Relay Control Module