Specification:
Item Type: Ethernet Remote IO Module
Material: Metal
Interface: Ethernet Port x 1, RS485 x 1, DIN x 16
Power Output: DC x 1
Working Voltage: 9-36VDC
Analog Quantity: 4-20mA
Plug Voltage: AC100-240V
Power Supply:
Input Voltage:
Not Supported AO Output: 9-36VDC
Support AO Output: 24-36VDC
Power Consumption: Typical Standby Power Consumption:2W
Power Output:
Channel
Output Voltage: 9-36V DC (Equal To Input Voltage)
Output Current: 1500mA at.12V (Maximum)
Power Protection: Anti Reverse Connection, ESD Air: 15KV, Surge: 4KV
Ethernet: Network Port Specification 1 x RJ45, 10M/100Mbps
Network Interface Protection: ESD Contact: 8KV, Surge: 4KV (10/1000us)
Protocol: for Modbus RTU, for Modbus TCP, MQTT
Serial Port:
Number Of Serial Ports: 1 x RS485
Serial Baud Rate: 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200, 128000
Data Bits: 7, 8
Check Bits: None, Eve, Odd
Stop Bit: 0.5, 1, 1.5, 2
Protocol for Modbus RTU (Slave), for Modbus RTU (Master)
Serial Port Protection: ESD Contact: 8KV Surge: 4KV (8/20us)
Digital Input:
Quantity: 16 Channels
Input Type: Supports Dry Contact and Wet Contact. The Default is Wet Contact. Dry Contact Needs to Be Described When Ordering;
Wet Contact Supports Both NPN and PNP Sensors
Dry Contact:
Closing: Short Circuit
Disconnection: Open End
Wet Contact:
Closed: 10-30VDC
Disconnection: 0-3VDC
Other: DIN1 is supported as pulse counter: high speed pulse and low speed pulse modes are supported. The default is high speed pulse frequency with a maximum of 700KHz, and the optional low speed pulse frequency with a maximum of 10KHz.
DIN2-DIN12 is supported as a low speed pulse counter: the anti jitter time can be set to 1-2000ms, the default is 1ms, and the maximum corresponding Pulse Frequency is 1KHz.
Isolation Protection: 2KVrms
Sampling Rate: 100Hz
Typical Applications:
Intelligent agricultural temperature and humidity data collection and monitoring;
Intelligent temperature and humidity data collection and monitoring of aquaculture;
Temperature and humidity data collection and monitoring in storage and library;
Data collection and monitoring of meteorological station information;
Temperature monitoring of cold storage, fruit and vegetable storage room, industrial machine room, transformer cabinet, etc;
Other occasions where monitoring points are scattered;
Data transmission of solar monitoring system, data acquisition and transmission of charging pile;
Data transmission of ATM, POS, electricity meter, PLC, DAQ and other equipment;
Smart grid data acquisition and control;
Intelligent traffic data acquisition and control;
Industrial automation data acquisition and control;
Environmental protection data acquisition and control
Features:
1Compatible Protocols: Communication protocols use standard for Modbus TCP protocol, for Modbus RTU over TCP protocol, MQTT protocol. 21 RS485 and 16 DIN: Adopt 1 RS485 communication interface, support standard for Modbus RTU protocol, for expansion, support 16 way din. 3Easy to Operate: Ethernet remote IO module can be managed and configured via LAN connection configuration software, easy to operate and maintain. 4LED Indication: Ethernet data acquisition module with LED to indicate the working status, with reset button for reset, easy to install and debug on site. 5IP30 Protection: With metal housing, protection level IP30, metal housing and system safety isolation, especially suitable for industrial control site applications. 6Wide Application: IO data module is designed to meet the needs of demanding industrial applications, can be used for industrial automation production, security monitoring systems, and automation control systems.
Package List:
1 x Module
1 x Guide Rail Clip
3 x Screw
1 x Instruction Card
1 x Power Adapter