Specification:
Item Type: Leakage Circuit Breaker
Material: Flame retardant nylon
Product Model: 1P+N 45mm
Working Current (In): 1-63A (adjustable)
Automatic Closing Delay Time: Less than or equal to 30s
Automatic Opening Delay Time: Less than or equal to 4s
Undervoltage Action Protection Time: 2-5s
Overvoltage Protection Time: 2-5s
Leakage Action Time: Less than or equal to 0.1s
Undervoltage Adjustable Range: 145v-195v
Leakage Protection Setting Range: 10mA-99mA
Width: Approx. 45mm / 1.8in
1. Operate on the Measurement Interface:
(1) Long press the "Set/Switch" key for 5S.
(3) Short Press the "clear/query" Button: You can view the total faults number of times in turn (at this time, overvoltage/undervoltage/overcurrent/leakage indicators are at the same time
(4) Long Press the "clear/query" Key for 5S: Clear all faults times.
(5) Short Press the "/Mute" Key: Can mute the buzzer sound.
(6) Short Press the "test" Button: Perform leakage function test.
2. Operate in the Setting Interface:
(1) Short Press the "Set/Switch" Key: Switch and set the overvoltage setting value, undervoltage setting value, overcurrent setting value, and leakage setting value in turn.
(2) Short Press the "/silence" Key: You can adjust the currently set value increase.
(3) Short Press "": You can decrease the currently set value.
(4) Long Press the "Set/Switch" Key: Exit the parameter setting. ; When the automatic reclosing power supply protector wiring is installed correctly, please connect the power supply. Turn on the "master control switch", and the automatic reclosing power protector will immediately turn on the circuit. Press the "Test" button, the auto-reclosing power protector will cut off the circuit, and the leakage indicator will be on, and the power will be restored automatically after 30 seconds. This means that the auto-reclosing power protector is working properly. At this point, you have correctly installed the Auto "Reclosing power supply protector", you can rest assured to enjoy the safety and convenience brought by automatic reclosing leakage protection.
Features:
1Possess the functions of overload protection, short circuit protection, leakage protection, over and under voltage protection, and over voltage recovery. Can prevent closing in the event of a fault, safer to use 2Come with anti-magnetic interference function, with electric closing, no electric opening 3Circuit breaks down immediately after the product is closed, which can be quickly opened to ensure the safety of electricity, and the contacts are always in a completely open or closed state to avoid the contact staying in the middle action due to fault to cause a safety incident 4The shell and parts are made of high flame retardant, high pressure resistant and impact resistant plastic 5There is a red control signal status light on the front of the product. When the voltage reaches the rated closing voltage, the status light is on; when the voltage is less than the rated voltage, the status light is off to identify the current control state of photovoltaic reclosing 6Circuit breaker has a fast closing function. Avoid the adverse effects of the speed of the handle in the automatic reclosing and opening of the circuit breaker, thereby prolonging the service life of the product
Package List:
1 x Leakage Circuit Breaker