Specification:
Item Type: Time Delay Relay
Module Control Terminal: There is a 3-wire interface, all interfaces have wiring terminals, which is convenient for users to use
1. DC+: DC power supply positive (5V, 12V and 24V modules are available)
2. DC-: negative pole of DC power supply
3. CH1: Input detection interface 1, active at high level
3. CH2: Input detection interface 2, active at high level
Relay Output Terminal: 6-wire interface, all interfaces have wiring terminals
1. NO1: Relay normally open interface 1, hang in the air before the relay is closed, and short-circuit with COM1 after it is closed
2. COM1: Relay common interface 1
3. NC1: Relay normally closed interface 1, short-circuit with COM1 before the relay is closed, and hang in the air after being closed
4. NO2: Relay normally open interface 2, hang in the air before the relay is closed, and short-circuit with COM2 after it is closed
5. COM2: Relay common interface 2
6. NC2: Relay normally closed interface 2, short-circuit with COM2 before the relay is closed, and hang in the air after being closed
The user can select one of the following 20 functions through the button and display, and can set and save the function parameters, or view the current function parameters. The time parameter setting can be adjusted at least 0.1 second, and the accuracy is better than 0.01 second. Setting operation instructions can be obtained from the seller. Reminder: Function 1-8 will start automatically when power on, function 9-18 needs high-level pulse signal (high-level duration is not less than 20ms, the same below) to trigger the start, function 19-20 needs continuous high-level .
Function 1: Timing pull-in: After power-on, delay T1 time relay pull-in, T1 is adjustable between 0.1 second and 270 hours, give a high-level pulse signal to the CH1 interface, and repeat the function more than once;
Function 2: Timing off: when power on, the relay is closed, the delay time T1 time relay is off, T1 is adjustable between 0.1 second and 270 hours, give a high-level pulse signal to the CH1 interface, and repeat the function more than once;
Function 3: Timing pull-in and then disconnection: After power on, the relay does not pull-in first, the relay pulls in after the delay time T1 arrives; the relay disconnects after the pull-in time T2 arrives, and the delay times T1 and T2 are between 0.1 second and 270 hours. Adjustable, give a high-level pulse signal to the CH1 interface, and repeat the function more than once;
Function 4: Timed disconnect and then pull-in: After power-on, the relay pulls in immediately, and the relay is disconnected after the delay time T1 arrives; the relay pulls in after the disconnection time T2 arrives, and the delay times T1 and T2 are between 0.1 seconds and 270 hours. Adjustable, give a high-level pulse signal to the CH1 interface, and repeat the function more than once;
Function 5: Infinite loop timing mode 1: After power-on, the relay does not turn on first, and the relay turns on after the delay time T1 arrives; the relay turns off after the turn-on time T2 arrives, and then repeats the above state, the delay time T1 and T2 are at 0.1 Adjustable between seconds and 270 hours, a high-level pulse signal to the CH1 interface can restart the above functions;
Function 6: Infinite loop timing mode 2: After power-on, the relay will be closed immediately, and the relay will be disconnected after the delay time T1 is reached; the relay will be closed after the off time T2 is reached, and then repeat the above state, the delay time T1 and T2 are within 0.1 seconds -Adjustable between 270 hours, a high-level pulse signal to the CH1 interface can restart the above functions;
Function 7: Limited cycle timing mode 1: On the basis of function 5, the cycle number function is added. At this time, T1 and T2 can be adjusted between 0.1 second and 9999 seconds, and the cycle number NX can be adjusted between 1 and 9999 times, to the CH1 interface A high-level pulse signal can restart the above functions;
Function 8: Limited cycle timing mode 2: On the basis of function 6, increase the number of cycles function, at this time T1 and T2 can be adjusted between 0.1 seconds and 9999 seconds, the number of cycles NX can be adjusted between 1-9999 times, to the CH1 interface A high-level pulse signal can restart the above functions;
Function 9: Self-locking relay mode: Give a high-level pulse signal to the CH1 interface of the relay, and the relay will pull in, and then give a high-level pulse signal to the relay to disconnect.
Function 10: Trigger relay mode: Give a high level signal to the CH1 interface of the relay, the relay will be closed, the high level will disappear, and the relay will be disconnected.
Function 11: Trigger timing pull-in: After power on, the relay will not act, give a high-level pulse signal to the CH1 interface, delay the T1 time relay pull-in, T1 can be adjusted between 0.1 seconds and 270 hours, and repeat a high level to the CH1 interface Pulse signal, repeat the function more than once;
Function 12: Trigger timing disconnection: After power-on, the relay does not act, give a high-level pulse signal to the CH1 interface, the relay is closed, the delay T1 time relay is disconnected, T1 is adjustable between 0.1 seconds and 270 hours, and repeats to the CH1 interface A high-level pulse signal, repeat the function more than once;
Function 13: Trigger timing pull-in and then disconnect: the relay will not act after power-on, give a high-level pulse signal to the CH1 interface, the relay will pull in after the delay time T1 arrives; the relay will disconnect after the pull-in time T2 arrives, and the delay time T1 and T2 is adjustable between 0.1 second and 270 hours, and repeat the function of giving a high-level pulse signal to the CH1 interface and repeating more than one time;
Function 14: Trigger timing disconnection and then pull-in: After power-on, the relay does not act, and a high-level pulse signal is given to the CH1 interface. The relay is closed immediately, and the relay is disconnected after the delay time T1 arrives; the relay is closed after the disconnection time T2 arrives. The delay time T1 and T2 are adjustable between 0.1 second and 270 hours. Repeat the function of giving a high-level pulse signal to the CH1 interface and repeat the function more than once;
Function 15: Infinite loop timing mode 1: The relay does not operate after power-on, and a high-level pulse signal is given to the CH1 interface. The relay is closed after the delay time T1 reaches; the relay is disconnected after the pull-in time T2 reaches, and then repeats the above state, delay The time T1 and T2 are adjustable between 0.1 second and 270 hours. Repeatedly give a high-level pulse signal to the CH1 interface to restart the above functions;
Function 16: Infinite loop timing mode 2: After power-on, the relay does not operate, and a high-level pulse signal is given to the CH1 interface. The relay will be closed immediately, and the relay will be disconnected after the delay time T1 is reached; the relay will be closed after the off time T2 is reached, and then again Repeat the above state, the delay time T1 and T2 can be adjusted between 0.1 second and 270 hours, and repeat a high level pulse signal to the CH1 interface to restart the above function;
Function 17: Limited cycle timing mode 1: On the basis of function 15, increase the number of cycles function, at this time T1 and T2 can be adjusted between 0.1 seconds and 9999 seconds, the number of cycles NX can be adjusted between 1-9999 times, repeat to CH1 A high-level pulse signal on the interface can restart the above functions;
Function 18: Limited cycle timing mode 2: On the basis of function 16, increase the number of cycles function, at this time T1 and T2 can be adjusted between 0.1 seconds and 9999 seconds, the number of cycles NX can be adjusted between 1-9999 times, repeat to CH1 A high-level pulse signal on the interface can restart the above functions;
Function 19: Conditional cycle mode 1: When the power is turned on, the relay is disconnected, and a high level signal is given to the CH1 interface. After the delay time T1 is reached, the relay is closed; after the pull-in time T2 is reached, the relay is disconnected. As long as the high level of the CH1 port does not disappear, The module will repeat the above actions. T1 and T2 can be adjusted between 0.1 second and 270 hours. If the high level signal of the CH1 interface disappears, the relay will be disconnected immediately and the function will be reset;
Function 20: Conditional cycle mode 2: When the power is turned on, the relay is disconnected, and a high level signal is given to the CH1 interface, the relay is closed, and the relay is disconnected after the pull-in time T1 reaches; the relay pulls in after the disconnection time T2 reaches, as long as the CH1 port is high-powered If the level does not disappear, the module will repeat the above actions, and the delay of T1 and T2 can be adjusted between 0.1 second and 270 hours. If the high level signal of the CH1 interface disappears, the relay will be disconnected immediately and the function will be reset.
Features:
1There are 5V, 12V and 24V modules to choose from, can satisfy your multiple needs. 2The user can select one of the following 20 functions by pressing the button and display, and can set and save the function parameters, and also view the parameters of the current function. 3The time parameter setting is adjustable by 0.1 second at minimum, and the accuracy is better than 0.01 second. 4Normally open port maximum load capacity: DC 030V/10A, AC 0/10A. 5Normally closed port maximum load capacity: DC 028V/10A, AC 0/10A.
Package List:
1 x Time Delay Relay