Specification:
Item Type: Temperature Humidity Controller
Material: ABS
Model: XY WTH1
Temperature Measurement Range: -20 to 60
Humidity Range: 00% to 100% RH
Control Accuracy: 0.1 0.1% RH
Detection Probe: Integrated sensor
Output Type: Relay output
Output Capacity: Up to 10A
Temperature Correction Function OFE (-10.0 to 10.0):
If the system works for a long time, there may be deviations. By using this function to correct, the actual temperature=measured temperature+calibration value;
How to set the start and stop temperature:
- In the running interface, press and hold the TM+ key for more than 3 seconds to enter the startup temperature setting interface. Testing can be done by modifying parameters using the TM+ TM- key. After the parameter modification is completed, wait for 6 seconds to automatically exit and save.
-
In the running interface, press and hold the TM- key for more than 3 seconds to enter the stop temperature setting interface. Testing can be done by modifying parameters through the TM+ TM- key. After the parameter modification is completed, wait for 6 seconds to automatically exit and save.
The humidity function is as follows:
-
Automatic recognition of working mode:
Automatically identify the working mode based on start or stop humidity.
Start humidity > stop humidity, dehumidification mode d ; Start humidity < stop humidity, humidification mode E.
- Dehumidification mode:
When the detection humidity isstart humidity, the relay is connected, the green indicator light is on, and the dehumidification equipment starts working.
When the detection humidity isstop humidity, the relay is closed, the green indicator light is off, and the dehumidification equipment stops working.
- Humidification mode:
When the detection humidity isstart humidity, the relay is connected, the green indicator light is on, and the humidification equipment starts working.
When the detection humidity isstop humidity, the relay is closed, the green indicator light is off, and the humidification equipment stops working.
-
Humidity correction function RH (-10.0 to 10.0):
If the system works for a long time, there may be deviations. By using this function to correct, the actual humidity=measured humidity+calibration value.
How to set start and stop humidity:
-
In the running interface, press and hold the RH+ key for more than 3 seconds to enter the startup humidity setting interface. During testing, parameters can be modified using the RH+ RH- key. After the parameter modification is completed, wait for 6 seconds to automatically exit and save.
- In the running interface, press and hold the RH- key for more than 3 seconds to enter the stop humidity setting interface. Testing can be done by modifying parameters using the RH+ RH- key. After the parameter modification is completed, wait for 6 seconds to automatically exit and save.
Features:
1Dual Output: The control module adopts dual relay outputs, which can control temperature and humidity, meeting various needs. 2Automatic Recognition: When the start temperature is greater than the stop temperature, enter cooling mode C; When the start temperature is lower than the stop temperature, enter heating mode H. 3Cooling Mode: When detection temperature isstart temperature, the cooling equipment starts working; When detection temperature isstop temperature, the cooling equipment stops working. 4Heating Mode: When detection temperature isstart temperature, the heating equipment starts working; When detection temperature isstop temperature, the heating equipment stops working. 5With Indicator Light: The temperature and humidity controller is designed with indicator light and the working status is clear and intuitive.
Package List:
1 x Temperature Humidity Controller