Features
1. Great Performance: This delay relay module is continuously adjustable from 0.1 seconds (minimum) to 999 minutes (maximum), realizing the circuit high frequency, fast and frequent on off, infinite switching times.
2. DC 5V to 30V: This time delay relay cycle control module uses 5 to 30V wide voltage work, can be used at most equipment, very convenient and practical.
3. Double MOS Switch Type: Using double MOS parallel active output, lower internal resistance, larger current, strong power, room temperature 15A, 400W, meet the use of most equipment.
4. Strong Anti Interference: With optocoupler isolation, enhance anti interference ability, industrial grade circuit board, even after setting parameters can be remembered forever.
5. Multiple Applications: Often used to control motor, light bulb, LED lamp belt, DC motor, micro water pump, solenoid valve, etc., through this module, you can easily control these equipment.
Specification
Item Type: Time Delay Relay Module
Material: PCB
Weight: Approx. 19g/0.7oz
Voltage Range: 5V to 30V
Trigger Signal Source: high level trigger (DC 3.0V to 24V) signal ground and system ground not common to improve the anti interference ability of the system (can also be self short circuited common ground)
Output Capacity: DC DC 5V to 30V, room temperature continuous current 15A, power 400W. Under the condition of auxiliary heat dissipation, the maximum current can reach 30A.
Static Current: 20mA
Working Current: 50mA
Service Life: unlimited switch
Operating Temperature: minus40 to 85
Function: With optocoupler isolation, enhance anti interference ability, industrial grade circuit board, even after setting parameters can be remembered forever
Timing range
0. 1 seconds (minimum) to 999 minutes (maximum) adjustable continuously
How to select the timing range:
After setting the parameter values in the mode selection interface, press STOP to select the timing range:
XXX. Decimal point in the one place, timing range: 1 second to 999 seconds
XX.X decimal point in ten, timing range: 0.1 seconds to 99.9 seconds
X.X.X. The decimal point is on. The timing ranges from 1 minute to 999 minutes
For example, if you want to set OP to 32 seconds, move the decimal point to the tens place. The nixie tube displays 03.2 Parameter description :OP on time, CL off time, number of loops LOP (1 to 999, "--" stands for infinite loops)
These parameters are independent of each other, but all modes share these parameters. For example, if P1 sets the on off time OP to 5 seconds, and the user wants to switch to P2 mode, then when P2 sets the corresponding parameter, OP will also be 5 second
Press the SET key on the main interface (display 000), and OP(CL, LOP) and corresponding time XXX will be displayed
If there is only OP(for example, P1) time in the mode, then pressing SET will only show OP and the corresponding time
If there is OP, CL, LOP(for example, P2, P3), then pressing SET will display OP and the corresponding time, CL and the corresponding time, LOP and the corresponding number of times;
After setting the mode, you can easily view the parameters SET in the current mode by pressing the Set key on the main interface, which is very convenient!
How to set parameters
1. Determine the working mode of the module
2. Based on the working mode of the module, the current worker blinks on the main screen (when the module is powered on) "Long press the SET key for 2 seconds and release" to enter the mode selection interface. Press the UP and DOWN keys to select the mode to be set (P0 to P 15)
3. Select a mode to be SET (for example, P3) and press Set to set related parameters
The set parameters will blink (OP on time, CL off time, LOP cycle times ("--" represents infinite cycles)), adjust parameter values through UP and DOWN, support long press (rapid increase or decrease) and short press (increase or decrease 1 unit). After setting the parameter value, press the STOP button to select the decimal point position and select the timing range (0.1 second to 999 minutes). Press the SET key to set the next parameter of the current mode. The process is the same as above
4. Select the mode to be SET (for example, P15) and press the Set key to set the corresponding mode parameter, the parameter to be set will blink (lower limit of CLL disconnect time, upper limit of CLH disconnect time, SP output speed (20 to 100%)), adjust the parameter value by UP or DOWN, support long press (rapid increase or decrease) or short press (increase or decrease 1 unit), timing range (corresponding time 0.1 seconds to 99.9 seconds); Press the SET key to set the next parameter of the current mode. The process is the same as above
5. After setting the parameters of the selected mode, press and hold the SET key for 2 seconds and release the set mode will blink, and then return to the main screen, setting parameters successfully, very simple!
Main interface: When the module is not working, "000" (no decimal point) is displayed. When the module is working, there is a decimal point, very clear!
Mode selection interface: Long press the SET key to enter, after the setting is complete, long press the SET key to exit and return to the master interface, very simple!
STOP button function extension: Module enable mode:
- ON: The module is allowed to be switched on during the OP switching time
-
OFF: The module cannot be switched on and is always off.
Press the STOP button ON the home screen to switch between ON and OFF. The current state will blink and then return to the home screen. (This function is the emergency stop function, one key to disconnect the closed module)
Sleep pattern:
-
C L sleep mode: within three minutes, without any operation, the digital tube automatically closes the display, procedure normal operation
- 0 d Normal mode: Nixie tube always open display
Press the STOP button for 2 seconds and release it to switch between C L and O d. The current state will blink and then return to the main interface.
Package List
1 x Time Delay Relay Module