Specification:
Condition: 100% Brand New
Item Type: Pain Relief Massager
Material: ABS + Aluminum Alloy
Host Size: Approx. 30 x 37 x 19cm / 11.8 x 14.6 x 7.5in
Frequency: 50-60HZ
Power: 180W
Output Frequency Gears: 16 Gears, continuously adjustable:
1HZ-2HZ-3HZ-4HZ-5HZ-6HZ-7HZ-8HZ-9HZ-
10HZ-11HZ-12HZ-13HZ-14HZ-15HZ-16HZ
Output Energy Gears: 25 Gears, continuously adjustable:
10mj-20mj-30mj-40mj-50mj-60mj-70mj-80mj-90mj-
100mj-110mj-120mj-130mj-140mj-150mj-160mj-170mj-
180mj-190mj-200mj-210mj-220mj-230mj-240mj-250mj
Contraindications:
Hemorrhagic disease: Patients with coagulation dysfunction may cause local tissue hemorrhage, and patients with untreated, untreated or incurable hemorrhagic disease should not undergo ESWT.
Patients with thrombosis: ESWT is prohibited in such patients to avoid the serious consequences of thromboembolic fall off.
Children with growth pain.
Patients with severe cognitive impairment and mental illness.
Operation preparation:
Treatment site of the patient is generally pain, acid, numb, stiffness, and limited range of motion of the joint, and the shockwave is a tearing damage, repair regeneration impact. It is recommended to "warm up" treatment with manipulation, passive training or physiotherapy before treatment. For example, ankle range of motion manipulation should be done before treatment of talus injury, muscle relaxation massage should be done before treatment of leg muscle spasm, and microwave therapy should be done before treatment of calcified supraspinatus tendonitis to promote microcirculation.
Methods:
A. Shunting: it spreads from the starting (stopping) point to the distal end of the muscle. Advantages: it is not easy to damage the normal tissue and does not aggravate the pain;Insufficient: Long frequency, long time.
B. Inverse beating: the direction is opposite to that of clockwise beating. Advantage: sometimes it can achieve amazing effect (knot principle).
C. Oblique shot: the gun is at a 45 degrees angle to the skin, especially suitable for soft tissue injury around the ankle joint
D. Parallel back and forth movement: it is a method of relieving pain during treatment and can also be applied to a wide range of lesions.
E. Circular movement: it is a method of relieving pain during treatment and can also be applied to a wide range of lesions.
Course of treatment: Generally 5-7 days once, 3-6 times for a course of treatment. Treatment time of extracorporeal shockwave therapy is about 5-15 minutes each time. For patients with short injury time, they can basically return to normal after one treatment. For old wounds, 5 to 7 treatments are required, with intervals of 3 to 7 days.
How to Use:
- Put the accessories and connect to the host.
(3) Choose a suitable working head. Hold the working handle with one hand, unscrew the working head from the working handle with the other hand (counterclockwise), and tighten the new working head (clockwise).
- In the interface
(1) Click "Basic Settings" to select language setting time
(2) Click the corresponding picture to be processed on the screen to enter the function interface.
The system includes 11 functional operating parts.
Take this manual elbow treatment as an example, click "elbow" in the interface to enter the interface.
-
In the "elbow" interface:
(1) "Preselect 2500 times" means that each time the system works to 2500 times, it will automatically pause. Follow the prompts to click anywhere on the screen.
(2) "Current" represents the working hours of the current course of treatment. Click "RESET" to clear the current number of treatments
(3) "Frequency 1HZ" means that the default operating frequency of the system is 1HZ, click "<" and ">" to adjust, the range is: 1HZ-16HZ
(4) "Energy 60mj" represents the default working energy of the system is 60mj, click "<" and ">" to adjust, range: 10-250mj
(5) Click the "" button to start working, and click "II" to stop working
Note:
-
Coupling agent can be applied to the affected area before treatment, and it is forbidden to pull the trigger in the state of empty gun.Do not turn on the output when the impact head is not in contact with the affected area to avoid unnecessary damage to the equipment and the patient.
- Shockwave therapy also has some side effects, including local tissue redness and swelling, subcutaneous hemorrhage, ecchymosis, pain, etc., but most of them are transient and can be alleviated or eliminated within 12 days after treatment.
- After treatment, drink plenty of water that day to promote circulation and expel inflammatory substances.
- At the early stage after the end of a course of treatment, try to reduce the power generated from sports or local injuries, and pay attention to rest for 12 weeks during treatment to make sure treatment sites
heal. The purpose of the coupling agent is first to fill the small gaps between the contact surfaces so that the air in those gaps does not affect the energy penetration.Secondly, the acoustic impedance difference between the probe and the skin channel is reduced by coupling agent "transition", thus reducing the reflection loss of ultrasonic energy at this interface.In addition, it also act as a "lubricant" to reduce the friction between the probe surface and the skin, enabling the probe to slide more flexibly.
Features:
1Shockwave therapy is a simple treatment process for strain diseases, noninvasive treatment, less harm to patients, shockwave therapy equipment has more obvious analgesic effect than other physical therapy equipment, especially for periarthritis of shoulder. 2Can be used for shock therapy of tumors and cancer cells in the whole system. Periarthritis of shoulder, patellar tendinitis, heel pain, etc. 3Urinary system of extracorporeal shockwave lithotripsy treatment, erectile dysfunction treatment. 4Seven different working heads are provided and the machine will recommend different working heads for different physiotherapy sites. 516 Frequency, 25 energy level, 5 preset times adjustable. Equipped with bracket, easy to store and display functional head.
Package List:
1 x Host
1 x Handle
1 x Base
2 x Rack
1 x Power Cable
7 x Working Head
3 x Spare Silicone Cover
1 x Manual