Features
1. It's wall-mounted designed will bring you much convenience and is very space-saving.
2. The rain and snow protection grade is up to IP65 with good air permeability and display function, which can display the current temperature and humidity in real time.
3. It is used in agricultural greenhouses, flower cultivation greenhouses, agricultural fields, electronic equipment production lines and other occasion requiring illumination monitoring.
4. The output signal type is RS485, which can communicate up to 2000 meters/ 2187yd.
5. Using special 485 circuit, 10-30v wide voltage range power supply, can keep the communication stable.
Specification
Condition: 100% Brand New
Item Type: Sensor
Material: PVC
Protection Grade: IP65
Size: Approx.13 x 11.7 x 4.2cm / 5.1 x 4.6 x 1.7in
Weight: Approx. 177g / 6.3oz
Wiring Method:
Wide voltage power input 10~30V can be. When wiring 485 signal line, note that the two lines A\B cannot be connected in reverse, and there should be no conflict between multiple devices.
Main technical parameters
DC Power Supply (Default) DC 10-30V
Maximum Power Consumption 0.4W
Transmitter circuit operating temperature and humidity -40~+60, 0%RH~80%RH
Probe Working Temperature-40~+120, Default-40~+80
Probe Working Humidity 0%RH-100%RH
Temperature Display Resolution 0.1
Humidity Display Resolution 0.1%RH
Temperature and humidity renovate time 1s
Output Signal RS485 (Modbus protocol)
Installation Wall mounted
A Accuracy Humidity 2%RH(5%RH~95%RH,25)
Temperature0.4(25)
B Precision (Default) Humidity 3%RH(5%RH~95%RH,25)
Temperature0.5(25)
Long-Term Stability Humidity 1%RH/y
Temperature0.1/y
Response Time Humidity 4s (1m/s Wind Speed)
Temperature15s(1m/s Wind Speed)
Wiring
Cable Color Specification
Power Supply Brown Power Supply Positive (10~30V DC)
Black Power Supply Negative
Communication Yellow 485-A
Blue 485-B
Communication parameters
Coding 8-bit binary
Data bits 8 bit
Parity check bit Non
Stop Bit 1
Error Check CRC (Redundant cyclic code)
Baud Rate 2400bit/s, 4800bit/s, 9600 bit/s Can be set, Factory default is 4800bit/s
Common problems and solutions:
The equipment could not be connected to a PLC or computer, there are possible reasons:
- The computer has multiple COM ports, the selected port is not correct
- Address error or devices with duplicate address (factory default is 1).
- Baud rate, calibration method, data bit and stop bit error.
- 485 is disconnected, or line A and B are connected in reverse
- Equipment wiring is too long, or too much should be nearby power supply, plus 485 enhancer, at the same time an increase of 120terminal resistance.
- USB to 485 driver is not installed or damaged.
- Equipment damage.