Feature:
- Power-off delay disconnection, there is signal - ON, no signal - delay OFF.
- Double output contacts.
- Each channel maximum current is 5A.
- Adjustable time range 0-30/0-300 and time unit second/minute.
- Rotate the adjustable resistor to setup delay time.
Specification:
Item Type: Delay Off Relay Module
Voltage: 12V DC (10-16V)
Power Consumption: <1.0W
Output: Passive Output (dry contact), two sets of relay NO + NC output. Do not exceed 5A in each group.
Life: 100,000 actions
Input: Voltage signal, valid signal above 1.5V, current needs at least 0.1mA
Terminal
V+: Power supply +
GND: Power supply -, also the reference GND for the signal voltage
IN: Signal voltage input, low level below 1V, high level above 1.5V, and uncertainty in the middle. Withstands up to 30V
NO1: Relay NO contact 1
NC1: Relay NC contact 1
COM1: Relay contact common terminal 1
NO2: Relay NO contact 2
NC2: Relay NC contact 2
COM2: Relay contact common terminal 2
Time Range Setting:
When the selector switch is set to 30 position, it means that 0-30 is adjustable
When the selector switch is set to the 300 position, it means that 0-300 is adjustable
Time Value Adjustment:
Turn the adjustable resistor counterclockwise to decrease the time and clockwise to increase the time
Time Unit Setting :
When the selector switch is set to the Sec position, the unit is: second
When the selector switch is set to the Min position, the unit is: minute
Example:
Requires a delay of 50 minutes:
- Set time range at 300 position
- Set time unit at Min position
- Adjust the adjustable resistor to the 50 position.
Application:
Use with limit switch and induction switch to achieve:
- Automatically close the door after timeout
- Assembly line product interruption monitoring
- Water/air flow interruption monitoring
Package List:
1 x Delay Relay Module