Features:
- Electrical parameter measurement function (voltage, current, active power, energy, frequency, power factor)
- Overload alarm function (over power alarm threshold, backlight and power flashing to alarm).
- Power alarm threshold preset function (can set power alarm threshold).
- The energy can be reset use the key.
- Store data when power off.
- Large-screen LCD
- Backlight function.
- Appearance and Key function
Specification:
Brand: PEACEFAIR
Model: PZEM-018
Working voltage: 80 ~ 260VAC
Test voltage: 80 ~ 260VAC
Current: 5A
Rated power: 5A/1100W
Operating frequency: 45-65Hz
Measurement accuracy: 1.0 grade
Size: 952.5cm/3.521in
Weight: Approx.85g/3oz
Package list:
1 * Digital Meter
Display Interface
Display interface is large-screen LCD, it can display six parameters at the same time.
II.Display format
- Power: test range: 0~1100W, Starting measure power: 0.2W
10Wdisplay format:1.00~9.99W
100Wdisplay format:10.0~99.9W
1000Wdisplay format:100~999W
1000Wdisplay format:1.00~1.10kW
- Energy: test range: 0~999kWh
1kWhdisplay format:0~999Wh
10kWhdisplay format:1.00~9.99kWh
10kWhdisplay format: 10~999kWh
- Voltage: test range: 80~260V
Display format: 80~260V
- Current: test range: 0~5A,Starting measure current: 0.001A
Display format: 0.000~5.000A
- Frequency: test range: 45~65Hz
Display format: 45~65Hz
- Power factor: test range: 0~1PF
Display format: 0.00~1.00PF
Key function
- Backlight control
Short press the key to turn on or off the backlight, the backlight has memory function, it can store the on or off state when power off.
- Reset energy
Step1: Long press the key for 5 seconds until the energy value flash, then release the key.
Step2: Short press the key again, then the energy value is cleared and exit the reset flashing state.
Step3:If there is no operation on the key within 5 seconds, it means the energy value is not cleared and will exit the reset state.
- Set power alarm threshold
Step1: Long press the key until the LCD screen display:SET CLr", then release the key to enter the setting state
Step2: Power window display the current power alarm value and the last digit begin to flash, then you can short press to plus 1, when there is no operating over 3 seconds, it will switch the digit position automatically, the setting method is as same as the above.
Step3: After finish the setting, long press the key over 5 seconds will store automatically and exit, the range of active power threshold is 0.0~2.5kW.
Note:
-
This module is suitable for indoor, please do not use outdoor.
-
Applied load should not exceed the rated power.
-
Wiring order can't be wrong.