Function
|
Test Item
|
Symbol
|
Test Condition
|
Minimum
|
Typical
|
Maximum
|
Unit
|
Over Charge Protection
|
Voltage
|
Vc1
|
At charge off
|
4.200
|
4.250
|
4.300
|
V
|
Delay
Time
|
Tc1
|
/
|
10
|
1000
|
1700
|
mS
|
Relieve
Voltage
|
Vc2
|
/
|
4.150
|
4.190
|
4.240
|
V
|
Charging
Current
|
Normal
|
Ioc
|
/
|
|
|
20
|
A
|
Balancing
Function
|
Start Voltage
|
|
/
|
4.150
|
4.200
|
4.250
|
V
|
Balancing
Current
|
|
/
|
20
|
|
35
|
mA
|
Over Discharge Protection
|
Voltage
|
Vd1
|
At discharge off
|
2.700
|
2.800
|
2.900
|
V
|
Delay
Time
|
Td1
|
/
|
10
|
200
|
500
|
mS
|
Relieve
Voltage
|
Vd2
|
/
|
2.900
|
3.000
|
3.100
|
V
|
Recovery
Condition
|
/
|
/
|
Disconnecting load
|
Over
Current Portecion
|
Over Current 1 Protection
Current
|
Ioc1
|
|
60
|
|
100
|
A
|
Over
Current 1 Protection Delay Time
|
Toc1
|
|
20
|
|
200
|
mS
|
Discharge
Over Current Relieving
|
Over Current Protecion Recovery
Condition
|
/
|
/
|
Disconnecting load
|
Discharge
Current
|
Max. Continuous Discharge
Current
|
Ioc
|
-
|
-
|
-
|
20
|
A
|
Short
Circuit Protection
|
Delay Time
|
Tshort
|
|
|
300
|
600
|
μS
|
|
Recovery
|
/
|
/
|
Disconnecting load
|
Internal
Resistance
|
Discharge Circuit Internal
Resistance(mΩ)
|
Ron1
|
|
/
|
/
|
20
|
mR
|
Self
Power Consumption
|
Working Mode
|
Icc1
|
|
/
|
20
|
50
|
μA
|