Specification:
Features:
The maximum speed current is 1A. External load common terminating + 24, the other end received the PLC output port Y.
Intermediate relay M: M0-M3071, the power loss preservation range can be set.
Specification:
Weight: 239g/8.4oz
Input point:8
Output point:6
Output current: 5A
Analog input: 6AD
Analog output: 2DA
Pulse output: No
Floating point: Support
Step motor: No support
Memory capacity:8000 step
Programming software: GX developer or GX works
Program steps: 8000 steps
Two communication ports:
One RS232 (DB9) serial communication port is FX3u protocol 38400,7, E, 1;
The output point Y element:
Y0-1 is high-speed output port (maximum 100K). PWM period is 0-32767US. High
The maximum speed current is 1A. External load common terminating + 24, the other end received the PLC output port Y.
Analog input:
Analog output:
Intermediate relay M: M0-M3071, the power loss preservation range can be set.
Step point S: S0-1023, power off storage range can be set to S0-S1023
100Ms timer: t0-t199, accumulative power off save t184-t199
10Ms timer: T200-T249, accumulative power off saving T246-T249
1Ms timer: T250-T383, where T250-255 is cumulative
16-bit counter: C0-C199, power off to save C100-199
32-bit counter: C200-C219, power off to save C220-C234
32-bit high-speed counter: C235-255; C235-240 is a single-phase counter, not frequency doubling; C241-240 is a single-phase counter with double frequency; C247-249 is a two-phase counter, not frequency doubling; C250-252 is a two-phase counter with double frequency; C253-255 is a two-phase counter, 4 times frequency;
Register D: D0-D7999, power off save range can be set to d0-7999,
Indirection pointer V, Z: V0-7, Z0-7
P subroutine jump number: P0-63
I interrupt: X0-5 external interrupt. Timer interrupt (1MS). The counter is interrupted.
Special M components: M8000 is normally closed when running, M8002 is electric pulse, M8011 is 10Ms pulse, M8012 is 100Ms pulse,M8013 is 1s pulse,M8014 is minute pulse.
Package List:
1x PLC Control Board
Features:
1Input point X element x0-x7, DC24 input, low level valid. X0-5 is the high-speed counting input port (default: 12K,100KHZ optional). 2Output analog voltage WR3A instruction, corresponding to the value 0-4095. 3The maximum speed current is 1A. External load common terminating + 24, the other end received the PLC output port Y. 4Y0-Y5 is optional relay or transistor output, relay output current 5A. The transistor output DC24V, the current maximum 1A. 5Intermediate relay M: M0-M3071, the power loss preservation range can be set.
Package List: