Specification:
Item Type: Relay Module
Trigger Signal: High Level: 12V, Low Level: 0V
Quiescent Current: 20mA
Working Current: 60mA
Working Temperature: -25-85
Power off Memory: Yes
Working Parameter Setting Description:
Press and hold the K1 button without letting go, the display will show P-xx after 2 seconds, press K2 and K3 to change the working mode. After selecting the working mode, short press the K1 key to enter the A time setting, and the screen displays Axxx. At this time, press the K2 and K3 keys to modify the A time parameter. Press the K4 key to set the position of the decimal point. After setting the A time, press the K1 key to set the B time, and the screen displays bxxx. At this time, press the K2 and K3 keys to modify the B time parameter. Press the K4 key to set the position of the decimal point. After setting the B time (when the mode has the C cycle number parameter), press the K1 key again to set the c cycle number, the screen displays Cxxx, at this time press the K2 and K3 keys to modify the c cycle number parameter, K2 and K3 keys Short press plus and minus 1, long press to fast plus and minus 10, after the setting is completed, press the K1 key one time to exit the setting state and save all parameters.
The Position of the Decimal Point and the Description of the Time Unit:
x.xx, the decimal point is in hundreds, the time range is 0.01-9.99 seconds
xx, the decimal point is in the tens place, and the time range is 0.1-99.9 seconds
xxx, no decimal point, time range 1-999 seconds
xxx, the decimal point is in the ones place, the time range is 1-999 minutes
Turn off the Display: In the non setting state, press K4 to turn off the display, then press again to turn it on again.
Working Mode (32 Kinds):
P-11: Jog mode, pull-in with signal, disconnect without signal.
P-12: Self locking mode, the state of the relay flips once after each trigger.
P-13: After triggering, the relay pulls in and disconnects after a delay of time A; triggering is invalid during the delay.
P-14: After triggering, the relay pulls in and disconnects after a delay of A time; triggers and times again during the delay.
P-15: After triggering, the relay pulls in and turns off after a delay of time A; the accumulative timing is triggered during the delay.
P-16: After triggering, the relay pulls in and disconnects after a delay of A time; triggers reset during the delay (relay disconnects).
P-17: After triggering, the relay is closed during the signal duration, the input signal disappears, and it is disconnected after a delay of A time; during the delay period, the relay is triggered again to remain closed, and the timing stops until the last signal disappears, and the delay A time After disconnecting.
P-18: After the power is turned on, the relay will be closed immediately and will be turned off after a delay of A seconds; until the next power on.
P-21: Give the signal, and the relay will be closed after a delay of time A.
P-22: Give a continuous signal. After the time A exceeds, the relay is closed; the signal disappears and the relay is disconnected.
P-23: When the signal disappears for more than time A, the relay is closed; when there is a signal, the relay is disconnected.
P-24: Give a continuous signal. After the time A exceeds, the relay will be closed; if the signal disappears for more than the time A, the relay will be disconnected.
P-25: Give continuous signal, after time A is exceeded, the relay will be closed; give continuous signal again, after time A, the relay will be disconnected
P-26: Give the signal, and the relay will be disconnected after being closed for A time; after the signal disappears, the relay will be closed again for A seconds and then stop
P-27: With pulse signal (rising edge or falling edge), the relay is disconnected, and there is no pulse signal. The relay will pull in after a delay of A time (continuous high level or continuous low level is considered as no pulse).
P-28: After power on, the relay will be closed after the delay time A until the power is off.
P-31: After power on, the relay will pull in for A time, disconnect for B time, infinite loop; power off stops.
P-32: There is a continuous signal, the relay is closed for A time, disconnected for B time, infinite loop; when the signal disappears, the loop is terminated.
P-33: Give a signal, the relay will pull in for A time, and disconnect for B time, infinite loop; give another signal to terminate the loop.
P-34: After power on, after delaying time A, the relay will be closed, and will be disconnected after the time B is closed.
P-35: Give a signal, after a delay of A time, the relay will be closed, and will be disconnected after being closed for 8 hours.
P-36: Give a continuous signal. After the time A exceeds, the relay will be closed, and will be disconnected after being closed for 8 hours; the signal disappears, the timer is cleared, and the relay is disconnected.
P-37: When there is a signal, the relay will be automatically disconnected after the A time is closed, and then the B time will be counted after the disconnection. The signal trigger is invalid within the A+B time.
P-38: When there is a signal, the relay will be automatically disconnected after the A time is closed. After being disconnected, it will be counted for 8 hours, and then it will be automatically disconnected after the A time is closed again.
P-41: No action when there is a signal; trigger when the signal disappears; the relay pulls in and disconnects after a delay of A time.
P-42: The signal disappears, the relay will be closed after a delay of A time; the relay will be disconnected after another 8 time delay.
P-43: The signal disappears, and the relay is closed after the disappearance exceeds the A time; the relay is disconnected after a delay of B time.
P-44: After power on, the relay will be closed for time A and disconnected for time B; the relay will be disconnected and stopped after c cycles.
P-45: No action after power on; after the signal is given, the relay will pull in for time A and off for time B; the relay will be disconnected and stopped after the cycle c; when the signal is given, it will be executed again.
P-46: After giving the signal more than A times, the relay will be closed; keep closed; power off and stop.
Features:
1Multifunctional Relay: The function of the module has been increased to 32, and users can use corresponding specific functions according to actual needs. 2Anti Reverse Function: With power supply anti reverse connection function, the module will not be damaged due to wrong power connection. 3High Accuracy: The timing range is 0.1s999min, the accuracy is 0.01s, the operation will be more precise and reliable. 4Power Saving Setting: With low power consumption and power saving settings, the display area can be turned off to extend the service life of the relay. 5Multiple Usages: Can be applied to water pump control, motor control, light strip control, solenoid valve control, etc.
Package List:
1 x Relay Module